{"id":887,"date":"2022-09-13T12:39:48","date_gmt":"2022-09-13T12:39:48","guid":{"rendered":"https:\/\/buildingphysics.groups.unibz.it\/?page_id=887"},"modified":"2022-09-13T14:49:21","modified_gmt":"2022-09-13T14:49:21","slug":"lab2","status":"publish","type":"page","link":"https:\/\/buildingphysics.groups.unibz.it\/?page_id=887","title":{"rendered":"LAB2"},"content":{"rendered":"\n<p class=\"has-large-font-size\"><strong>HVAC SYSTEMS LAB<\/strong><\/p>\n\n\n\n<p><strong>Lab description<\/strong><\/p>\n\n\n\n<p>The HVAC System Lab is intended for the characterization of the performance in variable conditions of handling units and heat recovery systems present in ventilation systems both for scientific research purposes and on industrial commission. The laboratory consists of a test chamber and two independent air circuits capable of reproducing experimental conditions for the analysis of the performance of ventilation system components in stationary and dynamic regimes.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"258\" src=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56-1024x258.jpeg\" alt=\"\" class=\"wp-image-933\" srcset=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56-1024x258.jpeg 1024w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56-300x76.jpeg 300w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56-768x194.jpeg 768w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56-1536x387.jpeg 1536w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/WhatsApp-Image-2022-09-13-at-15.12.56.jpeg 1599w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>HVAC systems lab.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Key competences and norms<\/strong><\/p>\n\n\n\n<p>The facilities of the laboratory allow the analysis of the aerodynamic, thermal and acoustic performance of Heat Recovery Systems (HRS) and air handling units (AHU), according to European standards EN 308 and EN 13141-7.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Scope of services<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Thermal and humidity transfer efficiency tests<\/li><li>Pressure drop test Leakage and crossover test <\/li><li>Acoustic tests <\/li><li>Air flow measurement <\/li><li>Electrical power measurement &nbsp;<\/li><li>In addition to the stationary conditions required by current standards, some tests may be conducted in dynamic regime.&nbsp;<\/li><\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"892\" src=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-1024x768.jpg\" alt=\"\" class=\"wp-image-892\" srcset=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-1024x768.jpg 1024w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-300x225.jpg 300w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-768x576.jpg 768w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-1536x1152.jpg 1536w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab2-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"891\" src=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-768x1024.jpg\" alt=\"\" class=\"wp-image-891\" srcset=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-768x1024.jpg 768w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-225x300.jpg 225w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-1152x1536.jpg 1152w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-1536x2048.jpg 1536w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab22-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"893\" src=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-768x1024.jpg\" alt=\"\" class=\"wp-image-893\" srcset=\"https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-768x1024.jpg 768w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-225x300.jpg 225w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-1152x1536.jpg 1152w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-1536x2048.jpg 1536w, https:\/\/buildingphysics.groups.unibz.it\/wp-content\/uploads\/2022\/09\/lab23-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption\">HVAC systems lab: overview of lab components.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button alignleft has-custom-font-size is-style-outline has-small-font-size is-style-outline--2\"><a class=\"wp-block-button__link\" href=\"https:\/\/buildingphysics.groups.unibz.it\/?page_id=24\">Back to Building Physics Labs<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HVAC SYSTEMS LAB Lab description The HVAC System Lab is intended for the characterization of the performance in variable conditions of handling units and heat recovery systems present in ventilation systems both for scientific research purposes and on industrial commission. The laboratory consists of a test chamber and two independent air circuits capable of reproducing experimental conditions for the analysis of the performance of ventilation system components in stationary and dynamic regimes. Key competences and norms The facilities of the laboratory allow the analysis of the aerodynamic, thermal and acoustic performance of Heat Recovery Systems (HRS) and air handling units [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-887","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/pages\/887","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=887"}],"version-history":[{"count":9,"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/pages\/887\/revisions"}],"predecessor-version":[{"id":1000,"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=\/wp\/v2\/pages\/887\/revisions\/1000"}],"wp:attachment":[{"href":"https:\/\/buildingphysics.groups.unibz.it\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=887"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}